20% OFF shipping at plataformaevia.es on orders over $79 + up to 10% OFF products
plataformaevia.es
home > ABB REJ603 | Numerical Relay for RMU & Secondary Distribution > ABB REJ603 | Numerical Relay for RMU & Secondary Distribution
download picture
ABB REJ603 | Numerical Relay for RMU & Secondary DistributionProduct Overview The ABB REJ603 (Part Number: 1VYV91248286) stands as a specialized numerical relay within the Relion 605 series, engineered specifically for secondary distribution switchgear and Ring Main Units (RMUs). This device utilizes a unique self powered design, drawing operational energy directly from the feeder current transformers. By eliminating the dependency on external auxiliary power supplies, the REJ603 ensures reliable protection in
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The ABB REJ603 (Part Number: 1VYV91248286) stands as a specialized numerical relay within the Relion® 605 series, engineered specifically for secondary distribution switchgear and Ring Main Units (RMUs). This device utilizes a unique self-powered design, drawing operational energy directly from the feeder current transformers. By eliminating the dependency on external auxiliary power supplies, the REJ603 ensures reliable protection in remote or unmanned locations where battery maintenance is impractical. We offer this unit as 100% Brand New and Original for critical infrastructure deployment.

Technical Specifications

Feature Details
Model REJ603 (Relion® 605 Series)
Power Supply Self-powered via Phase CTs (No external DC/AC needed)
Current Inputs 4 Channels (Selectable 1 A or 5 A)
Protection Stages Low-set and High-set Overcurrent & Earth-fault
Output Contacts Trip Contact & Alarm Contact
Fault Signaling LED Indicators and Mechanical Trip Flag
Accuracy Compliant with EN 60255-6 Standards
Operating Temp –25°C to +55°C
Environmental EMC Directive 2004/108/EC

Engineering Advantages

  • Zero-Maintenance Power Architecture: The REJ603 powers its internal electronics using the primary current through the CTs. This design removes the "single point of failure" associated with auxiliary battery banks and chargers, significantly reducing operational expenditure in rural or isolated grids.

  • Rapid Fault Signaling: Even in total darkness or power loss, the mechanical flag indicator provides a permanent visual record of a trip. This hardware-based signal assists field crews in identifying faulted sections immediately without needing to power up the relay's HMI.

  • Space-Efficient Integration: The compact housing fits perfectly into narrow RMU compartments. Its standardized mounting footprint allows for quick installation in both new panel builds and retrofitting projects where space is at a premium.

  • Deterministic Protection Performance: The unit employs two-stage non-directional overcurrent and earth-fault protection. These stages allow for precise grading with upstream and downstream devices, ensuring that only the faulted segment is isolated while maintaining power to the rest of the network.

  • Self-Supervision Intelligence: An internal watchdog continuously monitors the hardware and software integrity. If the relay detects an internal failure, it triggers an alarm, preventing "silent failures" that could leave a feeder unprotected.

FAQs

Does the ABB REJ603 require a minimum current to start up?

Yes. Since the unit is self-powered, it requires a minimum threshold current from the phase CTs to energize the electronics. However, the relay reaches operational readiness at very low load levels, ensuring protection is active long before a fault occurs.

Can I use the REJ603 with standard 1A or 5A Current Transformers?

The REJ603 supports both 1 A and 5 A secondary ratings. You must select the correct version or configure the inputs to match your specific CT ratios to ensure accurate measurement and trip timing.

How do I retrieve fault data if the feeder is de-energized?

The mechanical trip flag stays in the "tripped" position even after power is lost. For digital event logs, some versions support a temporary power interface or internal capacitor storage that allows engineers to extract data via the HMI or communication port after the event.

Is this unit compatible with IEC 61850?

The standard self-powered REJ603 focuses on autonomous protection. While higher-tier Relion models offer full IEC 61850 stacks, the REJ603 typically provides simplified signaling or optional HMI interfaces depending on the specific hardware variant (1VYV series).

ABB REJ603 | Numerical Relay for RMU & Secondary Distribution

Item no : 83866204864
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 7 - Jul 12

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches