REDUNDANCY FOR 2 PROTEGRASREDUNDANCY FOR 2 PROTEGRAS This fully automated redundancy circuit manages the operation of two Protegra CS RO systems in parallel connectivity with a downstream tank and two pressure booster pumps for the distribution of product water. By measuring the tank level, the two water treatment systems are operated alternately. When reaching a minimum or maximum pressure level or in the event of a system malfunctioning the second system is switched on or
Shopping security
Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
product description
Why choose thelockerguy wholesale?
REDUNDANCY FOR 2 PROTEGRAS
This fully automated redundancy circuit manages the operation of two Protegra CS RO systems in parallel connectivity with a downstream tank and two pressure booster pumps for the distribution of product water.
By measuring the tank level, the two water treatment systems are operated alternately. When reaching a minimum or maximum pressure level - or in the event of a system malfunctioning - the second system is switched on or off. Pressure sensors are controlling the two pressure booster pumps. The preset pressure levels of 1 bar minimum and 6 bar maximum can be adjusted. Should the tank level reach a minimum, the booster pumps are switched off (dry-running protection).
The redundancy circuit features the following for two water treatment and two pressure booster systems: - Alternating operation / changeover - Malfunction changeover in case of failure of one system - Peak load activation in case of high quantity withdrawals - A total of 5 potential-free alarm outputs (1 collective fault signal, 2 critical fault signals for system A/B, 2 non-critical fault messages for system A/B) for the connection to a building management system (BMS). - 2 start/stop signals for the water treatment systems - 2 motor protection switches connected to the Pressure boosting pumps.
Connections: - 2 outputs for start / stop water treatment systems - 2 outputs booster pumps (2x 2,2 KW maximum load) - 1 connection level sensor 4-20 mA for tank level - 1 connection pressure sensor 4-20 mA for pipeline pressure - Optional: Possibility to connect a conductivity measurement device and temperature measurement
E-connection: 3x 400 V, 50 Hz N/PE, fuse 3x C16A
Dimensions: W 300 x H 800 x D 155
Technical Specifications:
Mains voltage: 3x400V Voltage Pumps: 1x230V Pump type: regulated/ unregulated Analog outputs possible: 2 Start signal via level sensor: yes Start signal via ext. signal: no Analog outputs available: 0 Collective fault output x18: available EA Boards: 1 Hardness error message X17: not available Motor protection circuit: 2,5-4A System A RO Status X16: to extern: yes System B RO Status X17: to extern: yes System A Malfunction: to extern: no System B Malfunction: to extern: no Pump A Malfunction: to extern: no Pump B Malfunction: to extern: no Flow rate measurement Loop: available Temp.measurement Loop: available Conductivity measure. Loop: available Dual RO: available Discard tank/ Loop: available Measurement Feed water: available